Summary
Young's modulus Y = stress/strain is found for a metal wire by loading it and measuring the tiny extension. Searle's apparatus uses two identical wires, of the same material and length, hung side by side from one rigid support. The experimental wire carries the changing load. The reference wire carries a fixed load that only keeps it straight.
Plot the extension ΔL against the load F. Within the elastic limit the graph is a straight line through the origin (Hooke's law). The wire retraces the same line when the load is removed. Beyond the elastic limit, the graph bends, and on unloading the wire does not return to its original length.
Key formulas
- Young's modulus
- Y = FL / (AΔL) = 4FL / (πd²ΔL)
- Weight used as the load
- F = mg
- Slope of ΔL against F
- L / (AY)
- Slope of F against ΔL
- AY / L
- Y from the slope of F–ΔL
- Y = slope × L/A
- Energy stored
- U = ½ F ΔL
- Maximum percentage error
- ΔY/Y = ΔF/F + ΔL/L + 2Δd/d + Δ(ΔL)/ΔL
- Same load, same material
- ΔL ∝ L/d²
What this note covers
- Searle's apparatus method
- Load-extension graph
- Calculation of Young's modulus
The full note has 6 solved questions, 6 practice questions, figures and a topic test. Reading it on PrepKi is free after you log in.
PDF download is included in PrepKi plans. See plans.