Summary
Accuracy is how close a measurement is to the true value. Precision is how close repeated measurements are to each other, that is, the resolution of the instrument and the scatter of the readings. A set of readings can be precise but not accurate, if they are clustered but all shifted.
Least count (LC) is the smallest value an instrument can measure. The least count error is ± LC: it is the uncertainty in any single reading. For a vernier caliper, LC = 1 MSD − 1 VSD, which equals the value of one main scale division divided by the number of vernier divisions. For a screw gauge, LC = pitch ÷ number of circular scale divisions.
Key formulas
- Vernier least count
- LC = 1 MSD − 1 VSD = MSD / N
- Screw gauge least count
- LC = pitch / number of circular divisions
- Screw gauge reading
- MSR + CSR × LC − zero error
- Mean value
- a_mean = (a₁ + a₂ + … + aₙ)/n
- Absolute error
- Δaᵢ = |a_mean − aᵢ|
- Mean absolute error
- Δa_mean = (Σ|Δaᵢ|)/n
- Relative / percentage error
- Δa_mean/a_mean, (Δa_mean/a_mean) × 100 %
- Sum or difference
- ΔZ = ΔA + ΔB
- Product, quotient, power
- ΔZ/Z = ΔA/A + ΔB/B, ΔZ/Z = n ΔA/A
What this note covers
- Systematic and random errors
- Least count error
- Absolute, mean absolute, relative and percentage error
Solved past-paper question (NEET 2026)
Which of the following measurements require 'index correction'?
- (A) Measurement of speed of sound using resonance tube
- (B) Measurement of resistance of a wire using meter bridge
- (C) Measurement of gravitational acceleration using simple pendulum
- (D) Measurement of focal length of lenses using optical bench
Solution
Index correction is a systematic correction. It is needed when a quantity is read from a scale, but the real position of the object is not exactly at the scale mark.
Index correction: scale mark ≠ real position
On an optical bench, the object pin, lens holder and image pin are read on the metre scale at the holder, but the tips of the pins and the optical centre are not exactly at those marks.
Distances u and v are read from the holder marks
The other cases have different corrections: resonance tube needs an end correction, a metre bridge has end resistances, and the simple pendulum needs the radius of the bob added to the string length.
Resonance: end correction
Metre bridge: end resistance
Pendulum: length = string + radius
So the measurement of focal length of lenses using an optical bench needs index correction.
Answer: (D) Measurement of focal length of lenses using optical bench
Common mistake: Choosing the pendulum or the resonance tube: those have their own corrections (bob radius, end correction), not an index correction.
The full note has 6 solved questions, 6 practice questions, figures and a topic test. Reading it on PrepKi is free after you log in.
PDF download is included in PrepKi plans. See plans.