PrepKiYour AI companion for entrance exam preparation
NEET PHYSICS NOTES

Hysteresis and Permanent Magnets

NEET · Physics · Magnetism and Matter · Std XII

Summary

When a ferromagnetic specimen is magnetised and demagnetised by changing the magnetising field H, its magnetisation (and the flux density B) lags behind H. This lag is called hysteresis. Starting from an unmagnetised specimen, B rises along the first magnetisation (virgin) curve to saturation. When H is reduced to zero, B does not fall to zero. It is only brought to zero by a reverse field, and a full cycle of H traces a closed B–H loop.

Two intercepts of the hysteresis loop are important. Retentivity (remanence) is the value of B (or magnetisation) that remains in the specimen when the magnetising field is reduced to zero: it is the intercept on the B-axis. Coercivity is the reverse magnetising field…

Key formulas

Retentivity
B at H = 0 (intercept on the B-axis)
Coercivity
H at B = 0 (intercept on the H-axis); unit A m⁻¹
Field of a solenoid
H = nI (n = turns per metre)
Current to demagnetise
I = Hc/n
Unit conversion
20 turns per cm = 2000 turns per m
Energy lost per unit volume per cycle
W = ∮H dB = area of the B–H loop
Power lost in a core
P = (area) × V × f
Solenoid field
H = nI
Demagnetising current
I = Hc/n
Curie temperature
Ferromagnetic below Tc, paramagnetic above Tc

What this note covers

  • Hysteresis loop
  • Retentivity and coercivity
  • Choice of materials for permanent magnets and electromagnets

The full note has 6 solved questions, 6 practice questions, figures and a topic test. Reading it on PrepKi is free after you log in.

PDF download is included in PrepKi plans. See plans.